A practical way to separate mechanical load, motion profile, cooling, motor-cable and drive-sizing problems before replacing hardware.
| CAPTURE THE ALARM | CHECK THE LOAD | VERIFY COOLING |
An overload or overtemperature alarm does not automatically mean that the servo drive has failed. The protection may be responding correctly to excessive torque demand, a jammed mechanism, blocked airflow, an unsuitable motion profile, a motor-cable fault or a drive that is too small for the real duty cycle.
The safest approach is to preserve the alarm evidence first, then inspect the system from the machine toward the drive. Clearing the code repeatedly or increasing current limits before finding the cause can turn a recoverable condition into damaged power electronics, motor insulation or machine components.
| 01 |
First separate overload from overheating |
|
OVERLOAD
Current or torque demand is too highTypical directions include high acceleration torque, excessive process force, increased friction, a mechanical obstruction, incorrect motor data or insufficient drive sizing. The fault may appear quickly when motion starts. |
OVERHEATING
Heat generation exceeds heat removalCommon directions include sustained load, high cabinet temperature, dirty heat sinks, failed fans, blocked ventilation, incorrect mounting clearance or a cabinet cooling system that cannot remove the combined losses. |
| 02 |
Use the fault timing as the first diagnostic filter |
| When it happens | Likely direction | First checks |
|---|---|---|
| At enable or start | Brake not releasing, seized axis, motor or cable short circuit, incorrect motor setup | Brake command and voltage, uncoupled mechanical movement, cable insulation and motor data |
| During acceleration | Acceleration is too aggressive, reflected inertia is high or peak-current demand is excessive | Command profile, acceleration time, payload, gearing and peak-current trend |
| After steady running | Continuous load is too high, friction has increased or cooling performance has fallen | RMS current, heat-sink temperature, fan operation, filters, airflow and cabinet temperature |
| During deceleration | Regenerative energy, short deceleration time or braking-system limitations | DC-bus trend, braking resistor or regenerative unit, load inertia and deceleration ramp |
| 03 |
Product example: Rexroth TDM3.2-030-300-W1 |
|
MODULAR AC SERVO DRIVE
TDM3.2-030-300-W1
30 A continuous-current class
300 V maximum DC-bus class Traditional Indramat platform |
This legacy Rexroth Indramat module illustrates why the nameplate rating alone cannot diagnose an overload. The installed motor, mechanical duty, feedback configuration, cooling path and power-supply arrangement must work as one system. If a TDM3.2 drive begins tripping after years of stable operation, compare current and temperature behavior with an earlier healthy cycle. A change often points to rising mechanical resistance, deteriorated cooling, a motor or cable issue, or a process that now demands more torque. When replacement is considered, match the complete type code and verify the connected motor and system configuration. View TDM3.2-030-300-W1 Product Page |
| 04 |
A practical six-step troubleshooting sequence |
|
STEP 1
Preserve the evidenceRecord the exact alarm, timestamp, axis state, speed, torque, current, temperatures and recent machine changes before resetting anything. |
STEP 2
Make the system safeFollow the equipment lockout procedure, wait the specified discharge time and verify the absence of hazardous voltage before inspection. |
|
STEP 3
Inspect the mechanicsCheck jams, bearings, lubrication, alignment, gearbox condition, payload, brake release and whether the axis moves freely when safely isolated. |
STEP 4
Restore the cooling pathInspect heat sinks, fans, filters, cabinet air conditioning, mounting clearances and nearby heat sources. Clean only by approved methods. |
|
STEP 5
Verify motor, cable and feedbackLook for loose or discolored terminals, damaged insulation, phase imbalance, motor-cable faults and unstable feedback. Use manufacturer-approved test methods. |
STEP 6
Review sizing and parametersConfirm motor data, current limits, tuning, acceleration, duty cycle and continuous RMS demand against the approved machine design. |
| 05 |
What should be confirmed before replacing the drive? |
Confirm the cause: a new drive will not correct a jammed axis, failed cabinet fan or incorrect motion profile.
Match the identity: record the full part number, suffix, hardware revision, software or parameter backup and connected motor.
Preserve configuration: back up parameters and document wiring before removal whenever the system condition permits.
Plan recommissioning: verify grounding, feedback direction, limits, safety functions and low-risk test motion before returning to production.
Send the complete type code, revision, alarm information, photos, connected motor model, quantity and delivery destination. Our team can help compare available industrial automation parts for your maintenance plan.
| Sales manager | Yuki Huang |
| sales9@apterpower.com | |
| Mobile / WhatsApp | +86 17359287459 |
Safety note: Servo systems can retain hazardous voltage and can cause unexpected machine movement. Troubleshooting and recommissioning must be performed by qualified personnel using the documentation for the exact drive, motor and machine.
Tuyên bố miễn trừ trách nhiệm: Ewolomodule bán các sản phẩm mới và sản phẩm dư thừa và phát triển các kênh để mua các sản phẩm như vậy. Trang web này chưa được bất kỳ nhà sản xuất hoặc nhãn hiệu nào được liệt kê chấp thuận hoặc công nhận. Ewolomodule không phải là nhà phân phối, đại lý hoặc đại diện được ủy quyền của các sản phẩm được hiển thị trên trang web này. Tất cả tên sản phẩm, nhãn hiệu, thương hiệu và logo được sử dụng trên trang web này đều là tài sản của chủ sở hữu tương ứng. Mô tả, giải thích hoặc bán các sản phẩm có tên, nhãn hiệu, thương hiệu và logo này chỉ nhằm mục đích nhận dạng và không nhằm mục đích chỉ ra bất kỳ mối liên hệ nào với hoặc ủy quyền từ bất kỳ chủ sở hữu quyền nào.